Performance Data Sheet.
SmartWater Filtration System GNSV70FBL and GNSV75FWW
Using Filter FQSVF
■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI 42 and 53.
■ Actual performance may vary with local water conditions.
■ Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Standard No. 42: Aesthetic Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Chlorine — 2.0 mg/L ± 10% 1.94 mg/L <0.05 mg/L <0.05 mg/L 97.41% 97.22% >50%
T &O — — —— —— ——
Particulate** — ≥ 10000 particles 4100000 #/mL 24400 #/mL 67000 #/mL 99.35% 97.84% >85%
Standard No. 53: Health Effects
Turbidity 1 NTU*** 11 ±1 NTU*** 11.08 NTU 0.21 NTU 0.38 NTU 98.04% 96.20% 0.5 NTU
Cysts 99.95% red. Min. 50000L 141750 #/L <1 #/L 2 #/L >99.99% >99.99% >99.95%
Asbestos 99% red. 10
7
and 10
8
fibers/L; 168 MF/L 0.99885891 MF/L <1 MF/L 99.89% 99.82% >99%
fibers >10 µm long
Lead, 0.015 mg/L 0.15 mg/L ± 10% 0.147 mg/L <0.001 mg/L <0.001 mg/L 99.32% 99.29% 0.010 mg/L
pH 6.5
Lead, 0.015 mg/L 0.15 mg/L ± 10% 0.143 mg/L <0.001 mg/L <0.001 mg/L 99.30% 99.29% 0.010 mg/L
pH 8.5
Mercury, 0.002 mg/L 0.006 mg/L ± 10% 0.006033333 mg/L <0.0002 mg/L <0.0002 mg/L 96.68% 96.49% 0.002 mg/L
pH 6.5
Mercury, 0.002 mg/L 0.006 mg/L ± 10% 0.0058 mg/L 0.000333 mg/L 0.0005 mg/L 94.34% 92.06% 0.002 mg/L
pH 8.5
Lindane 0.0002 mg/L 0.002 mg/L ± 10% 0.002016667 mg/L <0.00002 mg/L <0.00002 mg/L 99.00% 98.95% 0.0002 mg/L
Benzene 0.001 mg/L 0.015 mg/L ± 10% 0.01417 mg/L 0.000500 mg/L 0.000500 mg/L 96.47% 96.43% 0.005 mg/L
Atrazine 0.003 mg/L 0.009 mg/L ±10% 0.00830 mg/L 0.002000 mg/L 0.002000 mg/L 74.82% 61.54% 0.003 mg/L
VOC Reduction
Chloroform 0.080 mg/L 0.30 ±10% 0.31429 mg/L 0.00186429 mg/L 0.0055 mg/L 99.40% 98.28% 95%
*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 160 gallons (605 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.60 gpm (2.27 l/min)
4
Replacement Filter Canisters/Estimated Replacement Costs
FQSVF—Replacement filter canister $35–40
For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
IOWA RESIDENTS ONLY:
Store or Seller’s Name
Address
City State Zip Telephone
Seller’s signature
Customer’s signature Date
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: February 9, 2004
160104-
Trademark/Model Designation
Replacement Element(s)
GXSV65 F FQSVF
GQSV65 F FQSVF
GNSV70 FBL FQSVF
GNSV75 FWW FQSVF
Cysts
Turbidity
General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Atrazine
Lindane
Benzene
VOCs
Organic Contaminants
Alachlor
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb
Simazine
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)
Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane
Xylenes
Endrin
Ethylbenzene
EDB
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
Methoxychlor
Pentachlorophenol
160 gal
Rated Service Capacity:
0.6 gpm
Rated Service Flow:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Manufacturer:
Asbestos
Lead
Mercury