GE IM-6 Ice Maker User Manual


 
69
Installation Instructions
CONNECT THE TUBING TO THE
REFRIGERATOR
(CONT.)
Place the compression nut and ferrule (sleeve)
onto the end of the tubing as shown. On GE
SmartConnect
Refrigerator Tubing kit,
the nuts are already assembled to the tubing.
Insert the end of the tubing into the water valve
connection as far as possible. While holding the
tubing, tighten the fitting.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end
of the tubing into the refrigerator connection
and tighten compression nut until it is hand tight,
then tighten one additional turn with a wrench.
Overtightening may cause leaks.
Fasten the tubing into the clamp provided to hold
it in a vertical position. You may need to pry open
the clamp.
Tubing
Clamp
1/4
Compression
Nut
Ferrule
(sleeve)
SmartConnect™
Tubing
Refrigerator
Connection
1/4Tubing
Tighten any connections that leak.
Reattach the compressor compartment
access cover.
TURN THE WATER ON AT THE
SHUTOFF VALVE
10
Arrange the coil of tubing so that it does not
vibrate against the back of the refrigerator or
against the wall. Push the refrigerator back to
the wall.
PLUG IN THE REFRIGERATOR
11
START THE ICEMAKER
Set the icemaker power switch to the ON position.
The icemaker will not begin to operate until it
reaches its operating temperature of 15°F (-9°C) or
below. It will then begin operation automatically if
the icemaker power switch is in the ON position.
NOTE: In lower water pressure conditions, the
water valve may turn on up to 3 times to deliver
enough water to the icemaker.
12
9