Henny Penny 342 Fryer User Manual


 
Model OFE/OFG/OEA/OGA-341, 342
2-15. GAS CONTROL VALVE
REPLACEMENT
(Continued)
5. Using a pipe wrench, loosen the outlet fitting to the burner.
Figure 2-41.
Figure 2-41
6. Using a Phillips screwdriver, remove the 2 screws securing
the gas valve to the bracket and remove gas valve from unit.
Figure 2-42.
7. Remove the fittings from the gas valve and install in new gas
valve.
Figure 2-42
8. Install the new gas valve in reverse order.
2-16. BLOWER MOTOR
The blower motor assembly induces the draft for the burners. If the
REPLACEMENT
blower motor fails, the air switch will fail to close, causing an
“E-20B” error code in the display.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove screws securing the rear cover to the unit.
Figure 2-43 Figure 2-43.
106 2-15