Henny Penny 342 Fryer User Manual


 
Model OFE/OFG/OEA/OGA-341, 342
2-6. TEMPERATURE PROBE 5. Remove the probe from the frypot, and disconnect wire
REPLACEMENT (GAS) connector from the control panel. Figure 2-15.
(Continued)
6. Place the nut and new ferrule on the new probe and insert the
probe into the compression fitting until it extends one (1) inch
(2.54cm) into the frypot. Figure 2-16.
7. Tighten hand tight and then a half turn with wrench.
Figure 2-15
Excess force will damage probe.
8. Connect new probe to PC board and replace control panel.
9. Replace shortening, and turn power on to check out fryer.
Figure 2-16
2-7. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature
REPLACEMENT (Gas) to the control board. If it becomes disabled, “E06” shows in the
REPLACEMENT display. Also, if the shortening temperature is out of calibration
(ELECTRIC) more than 10°F or C°, the probe should be replaced. An Ohm check
can also be performed. See chart on page 2-5.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
Figure 2-17 3. Remove screws securing rear cover of fryer, and remove rear
cover. Figure 2-17.
2-6 1209