Henny Penny 580 Fryer User Manual


 
Henny Penny Model 580
5-14. PREVENTIVE
MAINTENANCE
The following is a routine maintenance schedule for the Lid:
Every 90 days
Clean and reverse lid gasket
Yearly Cleaning and Inspection
Remove and clean Safety Relief Valve
Check Lid Gasket for splitting and tears - replace if necessary
Check Pressure Pads for wear - rotate if necessary
Check Cam Slide Guides - replace if worn or broken
Check Lid Rollers - replace if cracked or damaged.
5-15. REVERSING LID The gray rubber gasket surrounding the inside of the lid is designed
GASKET to be reversed. HENNY PENNY RECOMMENDS THIS BE
DONE EVERY 90 DAYS.
Because heat expansion and the pressure used for the cooking
process, the gasket is constantly under extreme stress. Reversing
the lid gasket every 90 days helps to assure the fryer won’t lose
pressure through leakage.
1. Open the lid completely, tilt lid back, and lock lid in place with
the “kickstand”.
2. Using a thin blade screwdriver pry out the gasket at the corners.
Remove the gasket.
“kickstand”
402 5-13