Henny Penny 580 Fryer User Manual


 
The Power/Pump Switch is a three way rocker switch with
a center “OFF“ position. With the switch in the POWER
position the fryer wiil operate. With the switch in the PUMP
position the filter pump will operate, but the heating unit will
not.
1. Remove Control Panel.
Remove electrical power suppled to the fryer by unplug-
ging the unit, or turning off the wall circuit breaker
or electrical shock could result.
2. “OFF” Position - should be open circuit anywhere on the
switch.
3. “Power” Position
Check from:
-5 to -6 closed circuit
-1 to -2 closed circuit
4. “Pump” Position
Check from:
#4 to #5 closed circuit
#3 to #2 closed circuit
Check across the jumpers on the wires of the
Power/Pump Switch. These jumpers have resistors and
capacitors which may be faulty.
1. With control panel removed and wires off of the switch,
push in on tabs on the switch to remove from the panel.
2. Replace with new switch, and reconnect wires to switch
following the wiring diagram.
3. Replace the control panel.