Henny Penny 580 Fryer User Manual


 
Henny Penny Model 580
5-21. OPERATING CONTROL
VALVE (Continued)
DO NOT MANUALLY ACTIVATE THE SAFETY
RELIEF VALVE. Hot steam will be released from the
valve when the ring is pulled. Keep away from safety
valve exhaust, or severe burns could result.
Cleaning Steps 1. AT THE END OF EACH DAY’S USAGE OF THE
FRYER, THE OPERATING VALVE MUST BE
CLEANED. The fryer must be OFF and the pressure
released. Open the lid and then remove the dead weight
ORIFICE CAP WEIGHT valve cap and dead weight.
Failure to clean the operating valve daily could result in
the fryer building too much pressure. Severe injuries and
burns could result.
2. Wipe both the cap and weight with a soft cloth. Make
certain to thoroughly clean inside cap, the weight seat, and
around valve orifice.
3. Dry the parts and replace immediately to prevent damage
or loss.
5-22. REMOVAL & CLEANING The safety relief valve should be cleaned once a year.
OF SAFETY VALVE
SAFETY VALVE
Do not attempt to remove valve while fryer is operating,
or severe burns or other injuries could result.
1. Remove pressure gauge.
2. Use a wrench to loosen the valve from the elbow, turn
counterclockwise to remove.
402 5-21