Hobart D300 Blender User Manual


 
12
Bowl Lift
The bowl lift mechanism should be lubricated twice a year. Loosen the knob and remove the bowl lift
access cover from the rear of the pedestal. Lightly coat moving parts (Fig. 6) with Lubriplate 630AA
(supplied). Replace access cover and tighten knob.
Bowl Lift Slideways
The slideways (Fig. 7) should be lubricated once each month. Remove the apron (secured by two thumb
screws) from the front of the pedestal. Lightly coat both slideways with Lubriplate 630AA (supplied).
Replace the apron and thumbscrews.
Fig. 6 Fig. 7
TROUBLESHOOTING
SYMPTOMS POSSIBLE CAUSES
Mixer will not start. 1. Gear shift lever between gears (not fully engaged).
2. Circuit protector in open position check fuse or
disconnect switch.
3. Mixer or attachment overloaded.
4. Bowl not all the way up.
5. Wire Cage Assembly is not in the front-center position.
FORM 18816 Rev. A (Feb. 2000) PRINTED IN U.S.A.
SERVICE
If service is needed on this equipment, contact your local Hobart Service Office.
PL-40171-1
Bowl Lift Mechanism
PL-40170-1
Bowl Lift Slideways