ELECTRICAL DATA
HR5E HR5E / HR5E *
VOLTAGE HZ PHASE AMPERAGE WATTAGE AMPERAGE
208(2W) 50/60 1 26.9 6000 53.8
240(2W) 50/60 1 25.0 6000 50.0
208(3W) 50/60 3 15.5 6000 31.0
240(3W) 50/60 3 14.4 6000 28.8
220/380(4W) 50/60 3 8.4 6000 16.8
230/400(4W) 50/60 3 8.7 6000 17.4
240/415(4W) 50/60 3 9.0 6000 18.0
Full load Amperage is measured at regulated voltage input.
* Stacked units can be wired independently or with single point connection using the stacking kit accessory.
SINGLE PHASE CONNECTION — 208V or 240V
TB1
12345678 9101112
123
L1 L2 L3
123317 45661
(3W) THREE PHASE CONNECTION — 208V or 240V
TB1
12345678 9101112
123
L1 L2 L3
12343317 4 9 5661
(4W) THREE PHASE CONNECTION — 220/380, 230/400, 240/415 VOLT
TB1
12345678 9101112
123
L1 L2 L3
1 34331795
1234
1
N
24661
TB4
ELECTRICAL DATA
HR7E HR7E / HR7E *
VOLTAGE HZ PHASE AMPERAGE WATTAGE AMPERAGE
208(2W) 50/60 1 42.8 9300 NA**
240(2W) 50/60 1 38.8 9300 NA**
208(3W) 50/60 3 24.7 9300 49.4
240(3W) 50/60 3 22.4 9300 44.8
220/380(4W) 50/60 3 12.9 9300 25.8
230/400(4W) 50/60 3 13.4 9300 26.8
240/415(4W) 50/60 3 14.1 9300 28.2
Full load Amperage is measured at regulated voltage input.
* Stacked units can be wired independently or with single point connection using the stacking kit accessory.
** Single point connection is not available for stacked HR7E / HR7E single phase units.