Hobart ML-132178 Oven User Manual


 
– 10 –
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE
PROVIDED WITH A THREE-PRONG GROUNDING PLUG. THIS PLUG MUST BE CONNECTED
INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT
THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE
GROUNDING PRONG FROM THIS PLUG.
The wiring diagram is located behind the side service panel on the right side of the oven.
Do not connect the HO300G gas model to the electrical supply until after gas connections have been
made.
The HO300E is an electrically heated oven consisting of six W-shaped elements, each rated at 3.0 kW
for a total input of 18.0 kW. The electrical input is shown in the table below:
Heating Circuit Supply Voltage
stloVzHesahPspmA
80206-05168
042-02206-05157-96
80206-05305
042-02206-05334-04
084-04406-05322-02
Both gas and electric ovens require a dedicated 15-amp, 110/120 V, 50 to 60 Hz, single-phase supply
with ground, connected at the control circuit terminal block located behind the right side service panel.
If oven is installed in conjunction with an HPC800 Proofing Cabinet, a separate 120 V supply is required
for the proofer.