7. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 87. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 8
7. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 87. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 8
7. WATER SUPPLY AND DRAIN CONNECTIONS - See Fig. 7 and 8
• Water supply inlet is 1/2" female pipe thread (FPT). A strainer should be installed with the
clean-out plug down. Locate the strainer in the water supply line, next to the ice
dispenser with the arrow on the strainer in the direction of the water flow.
Note: a) A Part Code 311166A01 strainer is an optional extra.
b) On water-cooled models, a 1/2" FPT is provided for the
Condenser Water Inlet.
• A water supply line shut-off valve and drain valve should be installed.
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If
the pressure exceeds 113 PSIG, use a pressure reducing valve.
• Two drain outlets are 3/4" female pipe thread (FPT).
Note: On the water-cooled model, a 3/8" - 18 FPT (3/8” diameter,
18 threads/inch) is provided for the Condenser Drain Outlet.
• The drains must have 1/4" fall per foot on horizontal runs to get a good flow.
• Keep more than a 2" air gap between drain pipe ends or hose ends and a floor drain.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• A back flow preventer may be required in some areas.
• Only cold drinking water will be used for this icemaker.