Hoshizaki KM-1300SAH-E Ice Maker User Manual


 
5
The opening for the power supply connection is
22.2 mm. diameter to fit a conduit.
• If a power cord is used to provide electricity to the icemaker
in place of the permanent (conduit) connection, a gland
should be installed at the 22.2 mm. power
supply
connection. This gland should be of the correct size for the
power supply cord being installed. The size of the
conductors of this power supply cord should be suitable for
the electrical consumption of this icemaker.
As the colours of the wires in the terminal box of this
appliance may not correspond with field supplied wiring or
with the markings identifying the terminals in your power
supply receptacle, proceed as follows:
The wire which is coloured Green-and-Yellow must be
connected to the terminal in the receptacle which is marked
with the letter E or by the symbol or
coloured Green
or Green-and-Yellow. The wire which is coloured Blue
must be connected to the terminal which is marked with the
letter “N” or coloured Black. The wire which is coloured
Brown must be connected to the terminal which is marked
with the letter L or coloured Red.
Usually an electrical permit and services of a licensed
electrician are required.
• For the electrical connection of the URC-12F-E remote
condenser unit to the fan motor junction of the KM-
1300SRH-E, an IPX4 rated conduit is recommended. If a
power supply cord is used, the cord itself should be certified
for outdoor use and a gland rated IPX4 should be used
where the cord enters the model URC-12F-E remote
condenser.
Usually an electrical permit and services of a licensed
electrician are required.
7. INSTALLATION OF REMOTE CONDENSER7. INSTALLATION OF REMOTE CONDENSER
7. INSTALLATION OF REMOTE CONDENSER7. INSTALLATION OF REMOTE CONDENSER
7. INSTALLATION OF REMOTE CONDENSER
UNIT (Remote Air-Cooled Model Only) UNIT (Remote Air-Cooled Model Only)
UNIT (Remote Air-Cooled Model Only) UNIT (Remote Air-Cooled Model Only)
UNIT (Remote Air-Cooled Model Only)
[a] UNPACKING[a] UNPACKING
[a] UNPACKING[a] UNPACKING
[a] UNPACKING
1) Unpack and remove shipping carton, tape(s) and packing.
2) Check that the refrigerant lines do not rub or touch lines
or other surfaces, and that the fan blade turns freely.
[b] LOCATION[b] LOCATION
[b] LOCATION[b] LOCATION
[b] LOCATION
The condenser unit is intended for outdoor use and must be
positioned in a permanent, well ventilated site under the
following guidelines:
Select a firm and flat site.
• Should not be exposed to harsh or adverse weather
conditions.
Fig. 5Fig. 5
Fig. 5Fig. 5
Fig. 5
6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION
WARNINGWARNING
WARNINGWARNING
WARNING
THIS APPLIANCE MUST BE EARTHEDTHIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHEDTHIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the na-
tional and local electrical code requirements. To
prevent possible severe electrical shock to individu-
als or extensive damage to equipment, install a
proper earth wire to the icemaker. Turn off the power
supply before any maintenance, repairs or cleaning
is undertaken.
This icemaker must have a separate power supply or
receptacle of proper capacity. See the Nameplate. It
is recommended that this icemaker be the only electrical
device on its power supply circuit.
• Stacked icemakers should each have a separate
receptacle, but they must all be connected in parallel
to the same single phase supply or circuit with sufficient
ampacity.
ENGLISH