Hoshizaki KM-1301SRH-E Ice Maker User Manual


 
22
c) Pump-Out Timer (S4 dip switch 3 & 4)
CAUTION
Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for this model.
Otherwise, pump motor does not rotate in the pump-out direction.
When a pump-out is called for, the pump motor stops after the preceding freeze cycle.
The pump motor restarts 2 seconds later in the reverse direction, taking water from the
bottom of the tank and forcing pressure against the check valve seat allowing water to
go through the check valve and down the drain. At the same time, water ows through
the small tube to power ush the oat switch. The pump motor drains the water tank for
the time determined by the pump-out timer. The pump-out timer also acts in place of
the harvest timer during cycles with a pump-out. The pump-out timer is factory set, and
generally no adjustment is required. The pump-out timer control can be set to pump-out
for 10 or 20 seconds.
S4 Dip Switch Setting Time (seconds)
Inlet
Water
Valve
No. 3 No. 4
T1
T2
OFF OFF 10 150 closed
ON OFF 10 180 closed
OFF ON 10 120 open
ON ON 20 180 closed
T1: Time to drain the water tank
T2: Harvest timer at pump-out
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory set to drain the water tank every 10 cycles,
and generally no adjustment is required. However, where water quality is bad and the
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The
pump-out frequency control can be set to have a pump-out occur every cycle, or every
2, 5, or 10 cycles.
Timing of the rst pump-out is dependent on S4 dip switch 5 & 6 settings. The rst
pump-out is factory set to occur after the 11th freeze cycle. See the table below.
S4 Dip Switch Setting
Pump-Out
Frequency
1st Pump-Out
No. 5 No. 6
OFF OFF Every cycle After 2nd freeze cycle
ON OFF Every 2 cycles After 3rd freeze cycle
OFF ON Every 5 cycles After 6th freeze cycle
ON ON Every 10 cycles After 11th freeze cycle