Hoshizaki KM-1301SRH-E Ice Maker User Manual


 
38
8) Shutdown
a) Thermostatic Bin Control: KM-1301SAH-E
When the unit is running hold ice in contact with the thermostatic bulb, the
thermostatic BC switch opens within 10 seconds, shutting down the unit (CB
red"POWEROK"LEDisoff).Thebincontrolisfactoryset,andgenerally
no adjustment is required. However, adjustment may be needed in some
conditions, particularly at higher altitude locations. Diagnosis:See"IV.C.1.
ThermostaticBinControlCheck."
b) Mechanical Bin Control: KM-1301SWH-E, KM-1301SRH-E
See"IV.C.2.a)MechanicalBinControlCheck."
Legend: BC–bin control; CB–control board; Comp–compressor; FM–fan motor; FMR–fan
motor-remote; F/S–oat switch; HGV–hot gas valve; HM–headmaster (C.P.R.);
LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve;
WV–inlet water valve