Hoshizaki KMD-410MWH Ice Maker User Manual


 
16
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper
Water Tubing or Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal ID Hard
Pipe or Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is suf cient extra water supply line and drain line for the appliance to be
pulled out for service.
Icemaker Water
Supply Inlet
1/2” FPT
Icemaker Drain
Outlet
3/4” FPT
Icemaker Water Supply Line
Shut-Off Valve
Icemaker Water Supply Line
Drain Valve
Bin Drain Outlet
3/4”FPT
Bin
2-inch
(5-cm)
air gap
Be sure there is suf cient extra
water supply line and drain line
for the appliance to be pulled
out for service.
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the drain.
Drain
Floor
KMD-410MAH
Fig. 9
Icemaker
Vent Tube
Vent Tube
Minimum 1/4” Nominal ID
Copper Water Tubing
Minimum 3/4” Nominal ID
Hard Pipe