Cornelius 2232MS Beverage Dispenser User Manual


 
6
0713
CenterIsland and Second Dispenser Installation
with Optional Syrup Tanks Hookup (see Figure
NO TAG)
Connect CO
2
, plain water, carbonated water, and
syrup lines between Beverage Control Panel
Assembly, the PostMix Dispensers, and other
equipment to be connected to the system. Optional
Syrup Tanks Kit (P/N 0673) is used to connect four
syrup tanks into the system.
Connect insulated plain water line between plain
water line connected to PostMix Dispenser cold
plate and the Orange Juice Dispenser.
CenterIsland Installation with Bulk Syrup Tank
Hookup (see Figure NO TAG).
Connect CO
2
, plain water, carbonated water, and
syrup lines between Beverage Control Panel
Assembly, the PostMix Dispenser, and other
equipment to be connected to the system.
Connect insulated plain water line between plain
water line connected to PostMix Dispenser cold
plate and the Orange Juice Dispenser.
CenterIsland and Second Dispenser Installation
with Bulk Syrup Tank Hookup (see Figure NO TAG).
Connect CO
2
, plain water, carbonated water and
syrup lines between Beverage Control Panel
Assembly, the PostMix Dispensers, and other
equipment to be connected to the system.
Connect insulated plain water line between plain
water line connected to PostMix Dispenser cold
plate and the Orange Juice Dispenser.
PREPARATION FOR OPERATION
BEVERAGE CONTROL PANEL ASSEMBLY
NOTE: The Beverage Control Panel Assembly
must be connected to a water source with water
pressure between 45 and 75PSI (3.10 and 5.17
Bars). If water pressure is over 75PSI (5.17
Bars), an Optional Water Pressure Regulator Kit
(P/N 30091900) must be installed. If plain water
source is below 45PSI (3.10 Bars), an Optional
Water Pressure Booster Kit must be installed in
the system to boost water pressure to 75PSI
(5.17 Bars).
IMPORTANT: DO NOT operate (if applicable) the
Optional Water Pressure Booster water pump
with no water connected to the Beverage Control
Panel Assembly. Operating water pump dry will
void its factory warranty.
1. Install looseshipped water filter cartridges on
water filter assembly.
2. Make sure all shutoff valves on water manifold
assembly and water filter assembly are in
‘‘OFF’’ position.
IMPORTANT: DO NOT operate carbonator(s)
water pump(s) or water pressure booster system
(if applicable) water pump with no water in the
system. Operating pumps dry will cause damage
to the pumps which will void their factory
warranty.
3. Connect plain water source line, meeting
requirements of preceding NOTE, to Beverage
Control Panel Assembly.
4. Open Beverage Control Panel Assembly plain
water source shutoff valve.
5. Beverage Control Panel Assembly equipped
with Everpure water filters (see applicable
Figure 3 or 5).
A. Connect length of garden hose to FILTER
‘‘ACTIVATION VALVE,’’ then route hose to
a permanent drain.
B. Open ‘‘ACTIVATION VALVE’’ and allow
approximately 28gallons of water to flow
through the water filters, then close valve.
6. Standard Installation (see Figure 7).
WARNING: CO
2
Displaces Oxygen.
Strict Attention must be observed in
the prevention of CO
2
(carbon
dioxide) gas leaks in the entire CO
2
and soft
drink system. If a CO
2
gas leak is suspected,
particularly in a small area, immediately
ventilate the contaminated area before
attempting to repair the leak. Personnel
exposed to high concentration of CO
2
gas
will experience tremors which are followed
rapidly by loss of consciousness and
suffocation.
Connect bulk CO
2
tank CO
2
supply line to barbed
fitting on CO
2
manifold. Secure connection with
tubing clamp.
Installation employing the optional highpressure
CO
2
Regulator Assembly Kit (P/N 0708) (see Figure
7)
WARNING: To avoid personal injury
and/or property damage, always
secure CO
2
cylinders with safety
chain to prevent them from falling over.
Should the valve become accidentally
damaged of broken off, CO
2
cylinder can
cause serious personal injury.