3
166240004
12/1/94
Rev 3/4/96
SPECIFICATIONS – 60 HZ
ICE CUBER SPECIFICATION
MODEL
IAC322E60
IAC330E60
IACS227E60
IWC322E60
IWC330E60
IWCS227E60
IAC522E60
IAC522E60L
IAC530E60
IAC530E60L
IWC522E60
IWC522E60L
IWC530E60
IWC530E60L
UNIT
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
No. Wires 2+ground 2+ground 2+ground 2+ground
MIN. CIRCUIT
Amps 15 15 15 15
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps 15 15 15 15
REFRIGERANT
Type R404A(HP62) R404A(HP62) R404A(HP62) R404A(HP 62)
Weight (oz) 17 15 26 23
Weight (g) 482 425 737 652
COMPRESSOR
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
LRA 24.1 24.1 45 45
RLA 5.7 5.7 9.2 9.2
CONDENSER FAN MOTOR (Air-Cooled Systems only) or
AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 0.89 0.36 0.89 .036
Watts 50 6 50 6
WATER PUMP
Volts 230 230 230 230
Phase 1 1 1 1
Hertz 60 60 60 60
Amps Running 0.5 0.5 0.5 0.5
HP 1/30 1/30 1/30 1/30