Cornelius IWC322 Ice Maker User Manual


 
6
166240004
12/1/94
Rev 3/4/96
SPECIFICATIONS 60 HZ
ICE CUBER SPECIFICATION
MODEL IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448
UNIT
Volts 230 230 230 230 230 230
Phase 1 1 1 1 1 1
Hertz 60 60 60 60 60 60
No. Wires 2+ground 2+ground 2+ground 2+ground 2+ground 2+ground
MIN. CIRCUIT
Amps 20 20 20 25 25 25
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps 20 20 20 25 25 25
REFRIGERANT
Type R404A(HP62) R404A(HP62) R404A(HP62) R404A(HP 62) R404A(HP 62) R404A(HP 62)
Weight (oz) 49 45 210 92 44 250
Weight (g) 1389 1276 5954 2608 1247 7088
COMPRESSOR
Volts 230 230 230 230 230 230
Phase 1 1 1 1 1 1
Hertz 60 60 60 60 60 60
LRA 96 96 96 95.6 95.6 95.6
RLA 13.5 13.5 13.5 23.9 23.9 23.9
CONDENSER FAN MOTOR (Air-Cooled Systems only) or
AIR CIRCULATION FAN MOTOR (Water-Cooled and Remote Systems only)
Volts 230 230 230 230 230 230
Phase 1 1 1 1 1 1
Hertz 60 60 60 60 60 60
Amps Running 0.89 X 2 0.36 0.36 0.4 0.36 0.36
Watts 50 W X 2 6 W 6 W 1/15 HP 6 W 6 W
WATER PUMP
Volts 230 230 230 230 230 230
Phase 1 1 1 1 1 1
Hertz 60 60 60 60 60 60
Amps Running 0.5 0.5 0.5 0.5 0.5 0.5
HP 1/30 1/30 1/30 1/30 1/30 1/30