- 4 - © 1999-2005, IMI Cornelius Inc.
A side water lever kit can be added to a valve
allowing for dispensing of water without syrup or
concentrate. The side water lever can be added to
either a carbonated drink valve or a noncarbon-
ated drink valve.
Post-mix valves control:
the ON–OFF of syrup and water,
the flow rates of syrup and water,
the mixing of the two ingredients as they pour into the cup, and
in some instances - dispensed portion.
3.2 Dimensions & Capacities
Fast Flow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 ½ to 3 oz./sec.
UFB-1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2 to 4 oz./sec.
Ultra Flow - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 to 4 ½ oz./sec.
Operational temperature range:- - - - - - - - - - - - - - 10°C (50°F) to 43°C (110° F)
Voltage requirements: - - - - - - - - - - - - - - - - - - - - 22 to 27 VAC (50/60 Hz)
Transformer (electronic valves) - - - - - - - - - - - - - - - - - - - - - - 80 VA min.
Operating Pressure (flowing)- - - - - - - - - - - - - - - - - - - - syrup = 20 psi min.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - water = 35 psi min.
Concentrates and juices that contain particulates must be dispensed from a juice valve.
A slanted drip tray is necessary when using an Optifill
TM
valve.
Concentrate valve sleeve
has only one hole
Syrup valve sleeve
has six holes
Mounting
screw
Water
lever