AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: N/A
SECTION 5: PARTS SECTION
60
HEATER ASSEMBLY
Heater Chart
Model Volts Phase KW Part Number
All* 208 1 10 06401-003-12-94
230 1 10 06401-003-12-95
208 3 10 06401-003-12-94
230 3 10 06401-003-12-95
460 3 10 06401-003-12-96
Heater Chart
Model KW 208V Models 230V Models 460V Models
All* 15 04540-121-68-45 04540-121-68-46 04540-121-68-47
* - “CS” & “CGP” models do not use electric heaters in the wash tank or power rinse tank.
SERVICE NOTE: When replacing the tub heaters, it is HIGHLY recommended that you also change out the gasket as well.
Once installed, gaskets become compressed and are subjected to extreme temperature changes. Replacing the gasket with a
new one when replacing the heater may prevent future leaks.
SERVICE NOTE: The nuts used to secure the heater to the tub should be torqued to 16 in-lbs. After tightening, the unit should
be allowed to heat up and operate normally for approximately 30 minutes. Secure power to the machine and check the nuts
once more to ensure that they are torqued to 16 in-lbs.
See Heater Chart Below
Heater Gasket
05330-011-47-79
5/16” Lockwasher
05311-275-01-00
5/16”-18 Hex Nut
05310-275-01-00