Cleaning the Ground Coffee Feed Funnel
Check approximately once a month that the feed funnel for
ground coffee is not blocked.
Cleaning the Inside
Check the inside of the coffee system approximately once a
week for dirt and debris. If necessary, remove coffee deposits
with a damp sponge or cloth.
Cleaning the Brewing Unit
Clean the brewing unit every month.
IMPORTANT: The brewing unit cannot be removed while the
coffee system is switched on. Do not attempt to use force to
remove the brewing unit.
1. Make sure the coffee system is properly switched off. See the
“Switching Off the Coffee System” section.
2. Open the service door on the front of the coffee system by
pulling on the hot water and steam spout.
3. Remove the drip tray and the coffee grounds container.
4. Press the two red release buttons inward and pull the brewing
unit out.
5. Soak the brewing unit in water for about 5 minutes, then
rinse.
NOTE: Do not use any detergent to clean the brewing unit.
The inside of the piston is treated with lubricant that
detergent would remove.
6. After cleaning, reinsert the brewing unit so that the support
and the pin at the bottom are fully engaged. Push the PUSH
symbol until it clicks into place and the two red release
buttons have clicked out.
NOTE: If you are having difficulty replacing the brewing unit,
compress the moving parts from both the top and bottom as
shown in the following illustration before reinserting it.
7. Replace the drip tray and coffee grounds container.
8. Close the service door.
A. Hot water and steam spout
B. Service door
A. Coffee grounds container
B. Drip tray
A
B
A
B
A. Red release buttons
B. Brewing unit
A. Support
B. Pin