Jenn-Air Range Range User Manual


 
14
6. Lift and rotate the motor 90° to reposition the electrical
connection.
7. Rotate bracket 90° and secure with 4 locknuts.
8. Remove the bracket from the other side of the blower motor,
rotate 90° and secure with 4 locknuts.
9. Position blower motor in cabinet opening and mount blower
motor to the floor.
10. Connect vent system to blower motor outlet (option 1 shown)
with 4 - #8 x ¾" hex head screws provided.
11. Go to the “Make Gas Connection” section.
A.Electrical connector
A
Top View
Option 1 Option 2
A.Inlet from range
B.Exhaust outlet
A.Inlet
B.Vent clamp
C.Floor
D.Vent system
A
A
B
B
A
B
C
D