27
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove access panel by grasping sides and pulling upward,
lifting out.
2. Locate gas pressure regulator behind access panel.
IMPORTANT: Do not remove the gas pressure regulator.
3. Unscrew the regulator cap and remove the plastic cover.
4. Flip the regulator cap over and replace the plastic cover.
5. Screw the regulator cap securely back into place. Do not
overtighten.
To Convert Oven Bake Burner
1. Remove oven racks from inside the oven cavity.
2. Remove the oven door. See “Oven Door” section in the Use
and Care Guide for oven door removal instructions.
3. Using a Phillips screwdriver, remove and set aside the 2 oven
bake burner cover screws located at the front of the oven.
4. Lift up and remove oven bake burner cover.
A.To range
B.Shutoff valve (closed position)
C.Gas supply line
A.Gas pressure regulator
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A
A.Plastic cover
B.Regulator cap
A.LP gas position
B.Natural gas position
C.Plastic cover
A.Oven bake burner cover
B.Oven bake burner cover screws
A
B
A
B
C
A
B