5. Use a ¹⁵⁄₁₆" combination wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
6. Gas supply pipe must not be more than 10" (25.4 cm) above
the floor.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from package
containing parts. Align recess in burner caps with pins in
burner base. Burner caps should be level when properly
positioned. If burner caps are not properly positioned,
surface burners will not light. Place burner grates over
burners and caps.
Connect Range to Downdraft System
1. Attach flexible vent (provided) to the blower motor inlet using
a vent clamp.
2. Check countertop height to allow range top to clear
countertop. Adjusting leveling legs if necessary.
3. Move range close to cabinet opening.
4. Plug into a grounded 3 prong outlet.
A.Gas pressure regulator
B.Use pipe-joint compound.
C.Adapter (must have ½" male
pipe thread)
D.Flexible connector
E.Manual gas shutoff valve
F. ½" or ¾" gas pipe
G.Use pipe-joint compound.
H.Adapter
A.Flexible connector
B.Manual shutoff valve
C.10" (25.4 cm) max. straight pipe
A.Closed valve
B.Open valve
A
B
C
D
E
FG
H
B
C
A
A
B
A.Inlet flexible vent
B.Vent clamp
1
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING