4. 3-Wire Power Cord Installation
-& WARNING: Theneutralor ground
wire of the power cord must be connected to
the neutral terminal located in the center of
the terminal block. The power leads must be
connected to the lower left and the lower right
terminals of the terminal block.
a, Remove the 3 lower terminal screws from the terminal
block. Insert the 3 terminalscrews through each power
cord terminal ring and intothe lower terminals of the
terminal block. Be certain that the center wire
(white/neutral) is connected to the center lower position
of the terminal block, Tighten screws securely intothe
terminal block,,
DO NOT remove the ground strap connection.
(appearance may vary)
Ground plato,
I
terminal
strap
b. Skip to Step 8 and proceed with the installation.
5. 4-Wire Power Cord Installation
WARNING: Theneutralwireof
the supply circuit must be connected to the
neutral terminal located in the lower center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block. The 4th
grounding lead must be connected to the
frame of the range with the ground plate
and the ground screw,
a, Remove the 3 lower terminal screws from the terminal
block, Remove the ground screw and the ground plate
and retain them,
b.Out and discard the ground strap. DO NOT DlSCARD
ANY SCREWS,
c. Insert the one ground screw into the power cord
ground wire terminal ring, through the ground plate and
into the frame of the range.
d. Insert the 3 terminal screws (removed earlier) through
each power cord terminal ring and into the lower
terminals of the terminal block,, Be certain that the
center wire (white/neutral) is connected to the center
lower position of the terminal block,, Tighten screws
securely into the terminal block,
Before //,_._
Terminal block
_i rap
Neutral
lermlnal
or
After
Termlna_
block /
Ground
screw
Neutral
terminal
Ground plate
(grounding to
range)
t
e. Skip to Step 8 and proceed with the installation
19