ELECTRICAL CONNECTIONS (cont.)
6. 3-Wire Conduit Installation
a. Loosen the 3 lower terminal screws from the terminal
block. Insert the center bare wire (white/neutral) tip
through the bottom center terminal biock opening. On
certain models, the wire wilt need to be inserted
through the ground strap opening and then into the
bottom center block opening., insert the two side bare
wire tips into the lower left and the lower right terminal
block openings.. Tighten the screws until the wire is
firmly secure (approximately 20 inch-lbs.).
DO NOT remove the ground strap connection,
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but it must be
rated for the correct amperage and voltage to make
connection. Connect wires according to this Step 6 or
Step 7 depending on number of wires°
Wire tips
Conduit
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes.
b. Skip to Step 8 and proceed with the installation.
7. 4-Wire Conduit Installation
a_
b,
Loosen the three lower terminal screws from the
terminal block. Remove the ground screw and the
ground plate and retain them Cut and discard the
ground strap. DO NOT DISCARD ANY SCREWS..
Insert the ground bare wire tip between the range
frame and the ground plate (removed eartier) and
secure it in place with the ground screw (removed
earlier).. Insert the bare wire (white/neutral) tip through
the bottom center of the terminal block opening.. Insert
the center two side bare wire tips into the lower left and
the lower right terminal block openings.. Tighten the
screws until the wire isfirmly secure (approximately 20
inch-lbs,),
block f !_
Ground strap f
After
_strap
X_ Neutral
termtnat
or
Wire
Ground
screw
Ground piale
(grounding to
range)
\N
Bracket
Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes,
c. Proceed to Step 8_