Keurig B3000 Coffeemaker User Manual


 
B3000 SERVICE MANUAL
60-200807-000, REV C 88
27.
HW Dispense valve “27:
HWD VALVE”
“MODULE:
BR-HEAD”
Open VV. Open
HWDV. Verify
HWT <0.1 psi after 2
seconds
Auto Continue if
OK
28. Transmit and receive
a “1” and “0”
through the coin IF
“29:
VEND I/F
LOOPBACK”
“MODULE:
M-PCB,
PWR-PANEL”
Auto Continue if
OK
29. Done “30: PASS, !!!!”
“DONE”
Power off Stop
Test 24 pressurizes the entire hot water part of the brewer, thus checking for leaks in:
All vent line components from the tank through the VV. Tested open in 25
The HWT
All fill line components from the HWT through the CWP. Tested open in 22
All brew line components. Not tested open
Test 25 pressurizes the cold water part of the brewer, thus checking for leaks in:
The vent line from the CWT to the bin. Not tested open
The CWT
The tube from the CWT to the CWP. Tested open in 22
The inlet valve and high pressure tubing. (to 4 psi) Tested open in 28
Some components are not tested. The functionality was tested by manufacturing.
Float valve
CWT and HWT drains open
Dispense line from Dispense Valve to Mug
TCOs opening and TCO sensors
Conductive probes and power
Inlet Valve
Hi-Pot
The coin IF loopback plug shorts the transmit to receive pin (RJ11 pins 3 and 4).