6. Remove the house wiring knockout.
7. Run the house wiring through the conduit connector (not
supplied) and into the dishwasher through the knockout
opening.
8. Secure the conduit connector in the knockout opening.
9. From the house wiring, strip 1/2" (13 mm) of insulation off of
each wire.
10. Insert the black supply wire and the white neutral wire into
the appropriate wire clamp on the terminal block. Securely
tighten the clamps.
1/2" (13 mm)
7
11. Place the ground wire under the green ground screw. Use a
7 mm socket wrench to securely tighten the green ground
screw.
12. Tighten the conduit connector. Replace electrical cover.
13. Pull the bottom drawer runners all the way out. Make sure the
latches on the back of each drawer runner are facing forward.
14. If the bottom drawer was rotated, rotate the drawer to unwind
the hoses and then put the drawer on the runners, making
sure the hoses are looping upward.
15. Make sure both runner clips have snapped into place. If they
have not, pull the runner clips forward until they do.
16. Close the bottom drawer.
terminal block
terminal block
ground wire
white wire
drawer
runner
latch
latch
bracket
conduit
connector
knockout
WARNING
Electrical Shock Hazard
Failure to do so can result in death or electrical shock.
Connect ground wire to green ground screw.
black wire
YD40643/8546448_E_non-RFI 10/1/04 9:42 AM Page 7