Kuppersbusch USA EEB 9800.0 Oven User Manual


 
22 EEB 9800.0 USA
Unscrewing/reinstalling the individual telescopic
glide-out shelves (acc.-no. 601)
Unscrewing the individual telescopic glide-out
shelves
If you want, you can screw the individual telescopic
glide-out shelves off the side walls with a screwdriver
so that it is easier to clean the walls.
For this purpose unscrew the bottom holding
screw on each side.
Reinstalling the individual telescopic glide-out shelves
Insert the individual
telescopic glide-out
shelves at the back
into the holes in the
intermediate wall and
screw the individual
telescopic glide-out
shelves at the bottom
front to the side walls.
Regenerating the ökotherm
®
catalyst
The ökotherm catalyst scrubs the grease particles and odor arising when
roasting in Hot air convection mode. The catalyst cleansing capability is usually
adequate. In rare cases of very intensive roasting of very large amounts of
food grease particles may settle on the catalyst. Next time you use hot air
convection, e.g. for baking a pizza, the deposits will be disposed of over time.
Should you feel the catalyst cleansing effect has weakened (e.g. if there is a
strong odour), the catalysts can be regenerated by removing the fatty deposits:
Select the programe Hot air convection
B.
Then touch the Rapid Heating sensor
J
.
Set the temperature to 555 °F / 290 °C and cooking duration u to
60 minutes.
Touch the sensor key
j.
What to do if trouble occurs...
=
Use a qualified technician for repairs!
However, there are some problems that you can handle yourself. First, check
and see if there have been any operating errors. Remember--repairs during
the guarantee period are not free of charge if they are caused by operating
errors or non-observance of the following instructions:
What is to be done if…
... neither sensors nor lighting function?
Please check: Is the mains plug in the wall socket? Is the domestic fusing
OK? Power failure?
... one or more sensors don’t react to touch but the lighting can
be turned on?
Possible cause: The sensors constantly adapt in sensitivity to ambient
conditions. Unfavorable conditions such as e.g. if you lean against them for
a lengthy period, may cause then not to react for several minutes.
Wait for about 15 minutes or pull the relevant fuse and then re-insert it.
Repeat this procedure if necessary!
The keys have adapted and now react to touch again.
... one or more sensors don’t react to touch despite repeating this
procedure?
Possible cause: Faulty sensor key or component.
If you’ve repeated the procedure and the keys still don’t react, pull the fuse
again and then contact our Customer Service.
... if <demonstration mode> is displayed and the oven won’t
heat?
Have this mode de-activated by Customer Service!
... the oven door glass cracked?
Switch the oven off and have the door replaced by Customer Service.
... the door sealing is damaged?
Replace the door sealing. (See page 23) Do not use the oven with a dama-
ged sealing!
...the oven lighting is defective?
The oven can still be used. Replace the halogen bulbs as soon as possible
- when the oven has cooled down - see “Replacing a halogen bulb”).
...there is a powerful odor?
Regenerate the ökotherm
®
-catalyst (see page 22).
... the oven generates a strong smell of vinegar?
Cooking a dish containing alcohol or yeast using programes with Hot air
convection will produce a vinegar smell.
If you find the smell disturbing, use
one of the modes without fan, such as Top/Bottom heat.
... fruit juice or albumin gets onto enameled surfaces?
This is a harmless enamel change that cannot be changed.