HYDRAULIC DIAGRAM
Pag. 5
HYDRAULIC CONNECTION
IMPORTANT: THE MANUFACTURER RECOMMENDS THE INSTALLATION
OF A DESCALING FILTER, THEREFORE HE WILL NOT ACCEPT RESPONSI-
BILITY FOR ANY DAMAGE CAUSED BY SCALE.
The machine can be installed as follows:
Table top installation:
Connect the mains pipe to the in-let electrovalve.
Check the pressure by the manometer, if it is over 1 bar, adjust it with the inside
reducer.
Cabinet installation:
Place the machine on the cabinet, insert the pipe with the filter, the one-way valve
and the float into the 15lt tank and the grey pipe into the 5 lt waste tank.
In order to discharge the coffee pucks into a bag, fix it up to the cabinet conveyer
with the special hook and insert the chute under the espresso brewer.
Finally screw the machine on the cabinet.
PAYMENT SYSTEM CONNECTION
12V PARALLEL connect to keyboard connector COIN12V (see picture
at page 7).
24V PARALLEL connect to keyboard connector COIN24V (see picture
at page 7).
EXECUTIVE / MDB connect to the relative cables (optional)
After the payment system connection, you must set the kind of payment system in
programming (see at page 15).