SWITCHING ON
When you switch on the machine, first the software version message will appear
on the display for a short time, and then the boiler heating will be shown by the
message "HEATING". The message ". ….INSERT THE CREDIT AND SELECT
YOUR DRINK…” will appear as soon as the right temperature is reached.
Note: we suggest doing a manual washing after you have switched on the ma-
chine, in order to fill more easily the hydraulic circuit and the boiler.
Please refer to the" quick functions" on page 24.
PROGRAMMING
There are 2 programming levels: a frequent menu and a main menu.
The frequent menu is useful to the operator in order to regulate the dosage of the
drinks, drinks dosing, to set the prices, to detect strokes read the counters and to
visualize the last machine operations.
The main menu is useful to the technical department in order to set the machine
parameters.
The programming buttons are the following: as follows:
1 Removes a drink or a movement from the menu setting drinks
2 Adds a drink or a movement into the menu setting drinks
3 Modifies a drink or a movement in the menu setting drinks
4 Executes a test of the drink in the menu setting drinks
5 Answer NO
6 Answer YES
7
8 (+) has the function of increasing or going on in the programming
9 (-) has the function of decreasing or going back in the programming
0 (ESC) to exit
E (ENTER) to confirm
Pag. 25
TROUBLESHOOTING GUIDE
The machine has a self-diagnosis program that allows you to visualize messages
of out of order.
ERROR GROUP 1 the coffee-group has not reached the “supply position” given by the
micro switch on its right side. Check fuses, group micro switch on the
right side, group motor and electronic board.
ERROR GROUP 0 the coffee-group has not reached the “standard position” given by the
micro switch on its left side. Check fuses, group micro switch on the
left side, group motor and electronic board.
ERR. COFFEE FLOW During espresso supplying, the board has not received signals from the
flowmeter. Check fuses, coffee quality, coffee pump, coffee electro
valve, flowmeter and electronic board.
ERR. SOLUB.FLOW During soluble supplying, the board has not received signals from the
flowmeter. Check fuses, soluble pump, soluble electro valve, flowmeter
and electronic board.
ERROR GRINDER 1 During the coffee grinding, the board has not received the signal given
by the doser-switch in 25 seconds. Check coffee quality, fuses, doser
micro-switch, grinder motor, grinder block and electronic board.
LACK OF WATER The board doesn’t receive the signal from the float. Check lack of wa-
ter, float, water container micro switch and electronic board.
ERROR BOILER 1 The board has not received the programmed value temperature from the
boiler sensor in 15 minutes. Check safety thermostat, boiler heating
element and electronic board.
EMPTY GROUNDS! The coffee grounds decounter has reached the programmed value.
Empty the grounds and execute the quick function no.5.
ERROR EXECUTIVE The board does not receive signals by the programmed Executive or
MDB payment systems. Check payment system, cables and electronic
board.
LACK OF CUPS The board doesn’t receive the signal from the cup-microswitch. Check
lack of cups and cups-microswitch.
ERR. CUP_RELEAS During the cup-releasing, the board has not received the change of state
of the cup-releaser micro switch. Fuses, cup-releaser motor, cup-
releaser micro switch, electronic board.
First you have to solve the trouble, then switch off the machine in order to delete