- 30 -
Unit must be disconnected from electrical outlet when making repairs, Re-
Placements, adjustments and continuity cheeks. wait at least one minute,
until the high voltage capacitor has fully discharged.
Ceramic Glass Part
Disassembly
1. Disconnect the power cord from the main source line.
2. Take the hob out from the structure.
3. Unfasten 10 screws from the side section.
4. Remove the ceramic glass part.
please carefully treat 2 hooks front and back side.
The hook should be inserted initially when the HOB is
assembled
DISASSEMBLY
LGE Internal Use OnlyCopyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes