Liebherr EWTN Beverage Dispenser User Manual


 
A delight in freshness
WFI1051 / EWTN 2956
8
INTEGRATING CABINETRY
Figure 5
IMPORTANT
If you are replacing the factory air vents with
an overlay, DO NOT restrict the air flow. The air
flow must be the same or greater than the fac-
tory air vents of 31 square inches (200 cm²).
The door handles must be installed before the
screw covers are installed. If you fail to install
the handles before the screw covers, you can
damage the covers. The screw covers are
taped to the unit doors during shipping. Use
care when removing covers.
The door panel weight must not exceed
25 lb (11,3 kg).
Framed Panels - Figure 5
If the thickness of the custom panels is less than
1/4" (6.4 mm), they must be backed up with a sheet
of shim material to build the total thickness to 1/4"
(6.4 mm). If the panel is thicker than 1/4" (6.4 mm),
an edge must be routed around the panel to
ensure a proper fit.
1/4"
(6.4 mm)
22-9/16" (573 mm)
32-37/64" (828 mm)
37-9/32" (947 mm)
1/4" (6.4 mm)
1/4"
(6.4 mm)
1/4" (6.4 mm)
= =
Window cutout
max. 17-1/2" (445 mm)
max. 25-1/2" (648 mm)
3-1/16"
(78 mm)