Lincoln 1300 Series Oven User Manual


 
CounterTop - 1300 Series Ops Manual
13
CONVEYOR REASSEMBLY
CONVEYOR BELT INSTALLATION
1. Put conveyor belt back on by setting the rolled belt to the left of the conveyor and thread approximately 2/3 of
the belt over the bottom slider bed.
2. Put the loose end of the belt around the idler shaft and back on the conveyor. The belt must lie on top of the
upper conveyor slider bed.
NOTE: The belt should curl around the conveyor sprockets and lay flat on top of the sprockets. If the belting does
not curl around the sprockets and lay flat, remove the belting and turn the belting over. Reinstall.
3. Pull all of the slack belt through conveyor until both ends are on top of the conveyor on the left end.
4. Reconnect conveyor belt by slipping the connecting links back in place.
NOTE: The conveyor belt of the Impinger
®
Conveyor Oven does not have a tension adjustment. If the belt would
become loose, a link will have to be removed to tighten. A belt that is too tight will also cause operational problems
due to excessive drag. We suggest that you have a qualified service technician perform this adjustment.
WARNING:
Careful consideration should be exercised prior to removing a belt link because a
belt that is too tight will impede the smooth operation of the conveyor.
!
CAUTION:
Do not work around conveyor belt with long hair, loose clothing, or dangling jewelry.
Getting caught in the belt could result in dismemberment or fatal injury.
!
CORRECT INCORRECT
CONVEYOR DRIVE
BELT
CAUTION:
BELT MAY BE HOT!
!
OVEN
BELT
CONVEYOR
ASSEMBLY