Magikitch'n MKG48 Griddle User Manual


 
L25-012 Rev 1 (08/02) 2
FUEL TYPES
Each appliance is equipped to work with one type of fuel. The type of fuel with which the appliance is
intended to operate is stamped on the data plate attached to the inside of the door.
NOTICE
NEVER use an adaptor to make a smaller gas supply line fit the cooker connection.
This may not allow proper gas flow for the optimum burner operation, resulting in
poor cooker performance.
QUICK DISCONNECT GAS CONNECTION
Gas appliances equipped with casters must be installed with connectors that comply with the Standard for
Connectors for Movable Gas Appliances, ANSI Z223.1 Latest Edition, and Addenda Z21.69A Latest
Edition. This connection should include a quick disconnect device that complies with the Standard for
Quick Disconnect Devices for Use With Gas Fuel ANSI Z223.1 Latest Edition. When installing a quick
disconnect you must also install a means for limiting the movement of the appliance. This device will
prevent the gas line or the quick disconnect from being strained. The restraining device should be attached
to the appliance at the back panel.
FUEL SUPPLY LINE LEAK AND PRESSURE TESTING
The fuel supply system must be tested before the appliance is used. If the fuel line is going to be tested at
a pressure greater than ½ PSIG (3.45 kPA), make sure that the appliance is disconnected from fuel line. If
the fuel line is to be tested at a pressure equal to or less than ½ PSIG (3.45 kPA), the appliance can be
connected, but the unit’s gas valve must be shut. Test all gas line connections for leaks with a solution of
soap and water when pressure is applied.