Magikitch'n MKG48 Griddle User Manual


 
L25-012 Rev 1 (08/02) 4
NOTICE
Legs are NOT intended to be used in conjunction with griddle carts.
C. FOR COUNTER USE WITHOUT LEGS: The appliance must be sealed to the counter to comply with
applicable sanitation standards. A bead of silicone sealant, approximately ½ inch wide, is to be
applied to the bottom of the unit approximately ¼” in from the front, back and side edges. We suggest
Dow Corning ®, GE ® or Permatex ® silicone ‘RTV’ adhesive sealant or equivalent. (See NSF Basic
Criteria C-2 for details).
D. FOR USE ON GRIDDLE CART:
NOTICE
When this appliance is installed with casters, it must be installed with the casters
supplied. A connector complying with ANSI Z21.69-CGA-6.16 and a quick
disconnect device complying with ANSIZ21.41/CAN 1-6.9. It must also be installed
with restraining means to guard against transmission of strain to the connector, as
specified in the appliance manufacturer’s instructions.
CAUTION
Only two of the four casters supplied have brakes. Be sure to install the two casters
with the brakes at the front of the unit. NOTE: Front brakes should be locked
before unit is placed into operation.
GAS HOOK UP:
An adequate gas supply is imperative. Undersized lines or low-pressures will restrict the volume of gas
required for satisfactory performance. A steady supply pressure between 7” and 8” w.c. for natural gas or
11” to 12” for propane gas is required. With all gas appliances operating simultaneously, the manifold
pressure on all gas appliances should not show any appreciable drop. Fluctuations of more than 25% on
natural and 10% on propane gas will create pilot problems and affect burner operating characteristics.
Contact your gas company for correct supply line sizes. After connection, all newly installed equipment
should be checked for correct gas pressure by a certified gas serviceman. The unit should be connected
ONLY to the type of gas for which it is equipped. Check the type of gas on the serial plate.
A. Attach regulator supplied with the appliance to the inlet of the gas manifold. Be sure regulator is
connected so that gas flow is in the direction of the arrow on the bottom of the regulator. Using a
regulator other than the one supplied with the unit will void the warranty.
B. The manifold pressure must be maintained at the pressure marked on the serial plate.
C. Use pipe joint compound that is suitable for use with LP gas on all threaded connections.
D. Turn off all thermostats
E. Turn on gas supply and check all connections for leaks using ONLY a leak checking fluid or
soapy water. NEVER use and open flame to check for gas leaks.
F. Provision must be made for adequate air supply for both the appliance and room occupants.
G. Keep area in front of unit free from obstruction that could block flow of combustion and/or
ventilation air.
H. Be certain that adequate clearance is maintained so that air openings in front of the unit are not
blocked and any subsequent service can be performed. Ensure that rear and side clearances stated
on the serial plate and in the clearance section of this manual are strictly followed.