Manitowoc Ice QF0400 Ice Maker User Manual


 
Section 6 Electrical System
Part No. 80-1214-3 6-51
4. Disconnect water level probe from control board. Install jumper from control board “water level” terminal to
ground.
5. Move the toggle switch from ICE to OFF to ICE position. Wait 45 seconds, then monitor the Water Level Probe
light.
WATER LEVEL PROBE CLOSED OR SHORTED
1. Disconnect the water level probe from the control board.
2. Move the toggle switch to the ICE position, wait 45 seconds and then monitor the Water Level Probe light.
Step 5 Jumper “water level” terminal to ground
Water Level light is: Compressor Cause
On Energizes
Replace water level probe wiring.
(Verify defective component – ohm wire from
connector to connector.)
Off Remains de-energized Replace control board.
Step 2 Disconnect water level probe from control board “water level” terminal
Water Level light is: Compressor Cause
Off Remains de-energized Clean water level probe.
On Energizes Replace control board.
SV2035
WATER LEVEL
PROBE LIGHT
DISCONNECT
WATER LEVEL PROBE.
JUMPER FROM
CONTROL BOARD
“WATER LEVEL” TO
GROUND
SV2036
DISCONNECT
WATER LEVEL PROBE.
WATER LEVEL
PROBE LIGHT
Revised 8/2003