Manitowoc Ice QF0400 Ice Maker User Manual


 
Section 6 Electrical System
Part No. 80-1214-3 6-19
RFC2085
Initial Start-Up
1B. WATER FILL
The condensing unit is off.
SV3040
RUN
CAPACITOR
(50)
(43)
(48)
COMPRESSOR
RUN
CAPACITOR
(47)
(46)
(49)
(44)
START
CAPACITOR
RELAY
S
C
R
52 1
(45)
OVERLOAD
CONTACTOR
CONTACTS
CONTACTOR
CONTACTS
CONTACTOR
COIL
LOW PRESSURE
CUT-OUT
HIGH PRESSURE
CUT-OUT
(96)
(94)
GROUND
L1
L2
COMPRESSOR
CRANKCASE
HEATER
(95)
(74)
FAN MOTOR
1B. Water Flush (Until Water Contacts Water Level Probe)
High Pressure Control CLOSED
Low Pressure Control OPEN
Contactor Coil OPEN / OFF
Compressor OFF
Condenser Fan Motor OFF
Revised 8/2003