Manitowoc Ice QF0400 Ice Maker User Manual


 
Troubleshooting Section 5
5-10
Part No. 80-1214-3
QF2200/QF2300
The evaporator and motor / gearbox are separate
assemblies. Warranty procedures require replacement
of the entire evaporator or motor /gearbox assembly.
Separate components are not available, and field
rebuilding during the warranty period is not allowed.
1. Disconnect power and water supply to the ice
machine and drain all water from the reservoir and
evaporator.
2. Remove reservoir retaining pin, water reservoir, ice
chute, and drain tubing (refer to Component
Removal).
3. Recover refrigerant and disconnect refrigeration
tubing from evaporator.
4. Remove foundation-coupling bolts.
5. Lift evaporator out of foundation coupling and
remove from ice machine.
6. Remove spline hub and keyway from evaporator
(8 mm hex wrench for coupling set screw).
7. Apply anti-seize compound to the shaft and all bolts
to ease future disassembly.
8. After reinstallation of evaporator, torque foundation
bolts to 195-205 inch lbs.
REMOVE
FOUNDATION
BOLTS
SV3017