Miele G 879 SCVI Dishwasher User Manual


 
4.Installing the custom door
panel.
A custom door panel must be installed
on the dishwasher before it can be
safely operated. A single large panel or
a two piece panel separated at the
drawer line can be used.
To open the dishwasher door
before
the front panel is installed, gently
pull on the upper portion of the
mounting bracket until the door latch
releases.
Panel Dimensions:
Weight: max. 9.5 kg
Thickness: 19 mm (3/4")
Width: 592 mm (23 3/8")
Height: To be calculated in accord-
ance with diagramm:
min. 700 mm (27 1/2")
max. 765 mm (30 1/8")
Note
If a split panel is used, the measure-
ments indicate the total combined
height of both panels plus the gap be-
tween them.
Front panel : Height F
F = C - 5 mm (1/4")
The door handle must be installed on
the panel before it is attached to the
machine. It should be located in the
center of the panel at a height that will
match the surrounding drawer handles.
Any screws used to attach the door
handle must be countersunk.
The maximum height from the under-
side of the countertop to the bottom of
the door panel is 770 mm (30 5/16").
To ensure safe operation of the dish-
washer once the panel is installed,
it is extremely important that the ten-
sion of the door springs be adjusted
to compensate for its weight. See
Step 7 for details.
Dishwasher installation
55