All electrical work should be carried out
by a competent person, in accordance
with national and local safety regula
-
tions.
Depending on the version, the appli
-
ance is supplied with a mains cable, or
a mains cable and plug for connection
to a.c. 50 Hz, 230 - 240 V.
The voltage, rated load and fuse rating
are given on the data plate situated at
the front of the oven interior. Please en
-
sure that these match the household
mains supply.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
Connection for the appliance should be
made via a suitable isolator which com-
plies with national and local regulations,
and which is accessible after the appli-
ance has been built in.
Test marks
Electrical safety, C-Tick Mark
Electrically suppressed according to
AS/NZS 1044
Important
The wires in the mains lead are col
-
oured in accordance with the follow
-
ing code:
Green / yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre
-
spond with the coloured markings iden
-
tifying the terminals in your plug, pro
-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or
coloured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured
red.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection AUS, NZ
59