All electrical work should be carried out
in strict accordance with national and
local safety regulations by a suitably
qualified and competent service
technician approved by Miele.
This appliance is supplied with a mains
cable and plug for connection to a 230
- 240 V, 50 Hz single phase supply.
The voltage, connected load and fuse
rating (where applicable) are given on
the data plate situated at the front of the
oven interior. Please ensure that these
match the household mains supply.
Connection should be made via a fused
connection unit or a fused plug and a
suitable switched socket, or via a
suitable isolator which complies with
national and local safety regulations,
and the on/off switch should be easily
accessible after the appliance has
been installed.
If the socket is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
When switched off there must be an
all-pole gap of 3 mm in the isolator
switch (including switch, fuses and
relays acc. to EN 60335).
For extra safety it is advisable to install
a residual current device with a trip
current of 30 mA (in accordance with
DIN VDE 0664, VDE 0100 Section 739).
If the cable is damaged a new cable
must be fitted by a Miele approved ser
-
vice engineer.
If the appliance is connected via an
isolator switch the plug must be cut off
and rendered useless. The appliance
must then be connected to the mains
supply by a suitably qualified person
only.
Important U.K.
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
Green/yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wires in the mains
lead of this appliance may not
correspond with the markings
identifying the terminals in your plug,
proceed as follows:
The wire coloured green and yellow
must be connected to the terminal in
the plug which is marked with the letter
E or by the earth symbol z or coloured
green or green and yellow.
The wire coloured blue must be
connected to the terminal marked with
the letter "N" or coloured black. The
wire coloured brown must be
connected to the terminal marked with
the letter "L" or coloured red (U.K).
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection IRL, U.K., ZA