* The appliance depth is increased
by approx. 35 mm for appliances
with wall spacers fitted.
a Top box
b Appliance
c Housing unit
d Wall
The appliance can be installed in a
kitchen run. To match the height of the
rest of the kitchen, the appliance can
be fitted with a suitable top box a.
A ventilation gap of at least 50 mm
depth must be allowed for behind the
appliance across the entire width of the
top box for air to circulate.
The cross section of the air outlet under
the room ceiling must be at least
300 cm
2
to ensure that air can circulate
without hindrance. Otherwise the
appliance has to work harder, resulting
in an increase in electricity
consumption.
The ventilation gaps must not be
covered or blocked in any way.
They should be dusted on a regular
basis.
When built into a kitchen run (max.
depth 580 mm) the appliance can be
installed directly next to a kitchen
furniture housing unit. The appliance
door will protrude in front of furniture
fronts at the sides by 34 mm* and by
55 mm* in the middle of the door. This
enables the door to be opened and
shut without being obstructed.
When installed next to a wall d a
distance of approx. 30 mm must be
maintained on the hinge side between
the wall d and the appliance b,so
that the doors and the handles have
sufficient space for opening.
Installing the appliance
47