Adjustment of minimum level for the hob
burners
The burner is correctly adjusted when the flame
is stable silent and goes out without any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is
correct when the flame is about 4 mm in length.
The top burners do not need adjustment of
primary air.
Check that, turning the knob quickly from the
maximum position to the minimum one, the flame
does not go out.
Hob burners
To adjust the minimum level:
Light the burner
Turn the knob to the position of the minimum
flame;
Remove the knob;
Unscrew or screw the by-pass screw (on the
right above of tap shaft) until a regular small
flame is reached.
For LPG screw completely the by-pass
screw.
Reassemble the parts following the same
procedure in reverse.
Check that, when turning the knob quickly from
the maximum position to the minimum one, the
flame does not go out.
Replace the nozzles of the oven burners
Oven burner
To replace the gas oven nozzle, follow this
procedure:
Check the table no.1 for diameter of nozzle;
Remove the oven removable base panel;
Remove the screw on the oven burner rod at
the rear of the oven;
Remove the oven burner by pushing it
backwards.
Replace the nozzle by means of a No 10
socket spanner;
Reassemble the parts following the same
procedure in reverse.
Grill burner
To replace the gas grill nozzle, follow this
procedure:
Remove the grill burner after removing the
fixing screw.
Replace the nozzle by means of a No 10
socket spanner;
Refit all parts and test.