3
Warning:
Electrical and grounding connections must comply with all local electrical codes or in the
absence of local codes then connections must comply with the National Electrical Code.
Warning: When working on the dishwasher, disconnect the main electric service and tag it to
indicate work is being done on that circuit.
1. Theelectricianshouldcomparetheelectricalspecicationsonthemachineelectricaldata
plate (located in the control panel) to the electrical power supply before connecting the
machine to the incoming service at a fused disconnect switch.
IMPORTANT: The 208-240V/60Hz/1PH electrical supply service for this machine must be a
2-wire plus ground service. For optional 208-240V/60Hz/3PH the electrical supply service
must be a 3-wire plus ground service.
2. On the 208V-240V models, a knockout is provided at the rear of the junction box for
electrical service connections. A fused disconnect switch or circuit breaker (supplied by
user) is required to protect each power supply circuit.
Note:
Leave enough electrical cable behind the machine so that the dishwasher
can be pulled forward a minimum of two feet to be serviced.
Electrical Connections
Refer to the MACHINE ELECTRICAL CONNECTION DATA PLATE for the
dishwasher power requirements.
Installation