Norcold 442 Refrigerator User Manual


 
Side Wall Clearance - Figure 4
1. Fi
g
ure 4 illustrates the re
q
uirement to minimize
the clearance at the sides of the refri
g
erator.
The clearance is not to exceed 1/2 inch. Side
clearances in excess of 1/2 inch must be either
filled with Fiber
g
las battin
g
or blocked with pan-
elin
g
, etc.
Upper Side Wall Exhaust Vent For Mod-
els 452, 453, 442, and 443 ONLY
Figure 5
1. Area above refri
g
erator blocked
(
baffled
)
off to
prevent trappin
g
of hot air above the refri
g
era-
tor.
2. 0 - 1/4 inch clearance at the top of the refri
g
-
erator.
3. Upper Side vent Location. Floor level to top of
openin
g
. 38 1/8" for models 442 & 443. 50 1/2"
for models 452 & 453. See Table 1 for vent
dimensions,
4. 0 - 1 inch clearance at the rear of the refri
g
era-
tor.
(
See Fi
g
ure 3 when clearance exceeds 1
inch
)
.
5. Intake
(
lower
)
vent installed flush with the sur-
face on which the refri
g
erator is mounted.
6. O inch clearance at bottom of refri
g
erator.
Top and Side Wall Clearance-All Models
Figure 6
1. Top baffle fills the total area above the refri
g
-
erator an is properl
y
ali
g
ned with the side wall
construction.
2. 0 - 1/2 inch at the sides of the refri
g
erator.
3
6
4
5
2
1
2
Fi
g
ure 5
1
B
1
Fi
g
ure 4
1
2
Fi
g
ure 6
7