Panasonic NE-C1153 Microwave Oven User Manual


 
- 23 -
When oven is placed on a counter top, its base
must be sealed in accordance with N.S.F.
Standards as per the following instructions.
1. Oven should be located on a level counter top
surface. Complete the electrical connections.
2. Thoroughly clean and sanitize the oven bottom
perimeter and the counter top area around the oven
perimeter.
3. Remove the Air Screens from the front of the oven
before applying high temp. silicone.
4. Lay generous bead of high temp. silicone seal
around the entire perimeter of the base of each
oven unit.
5. Smooth the silicone seal into the crevice with finger
or tool to provide a cove seal.
Note: DO NOT FORGET to re-install the Air Screens
after applying high temp. silicone.
Sanitary Counter Top Seal
Silicone
Sealant
Counter Top
Self Diagnostics Failure Code Explanation
Your oven is equipped with a Self Diagnostic Failure Code System: This means the oven monitors its own
operation and will show a Failure Code in the display window in the unlikely event of a malfunction.
If a Failure Code appears in the display window, follow these steps:
(It will appear as an “F” then a two digit number)
eg.
1. Close the door and unplug the oven at the main socket. Ensure all air vents are clear.
2. Leave 1 minute and then reconnect the oven at the main socket.
3. Open the door and place food or a jug of water in the cavity, close the door.
4. Try the same function that had been in operation prior to the appearance of the Failure Code in the display
window.
If the Failure Code appears again, then contact the dealer from whom you purchased the oven.
What to do when a failure code appears:
CODE
F01
F05
F30
F44
F09
CAUSE
• Overcooked food.
• Temperature of exhaust air too high.
• Defective Memory IC.
• Defective thermistor circuit.
• Defective control panel.
• Incoming line frequency is not matched.
WHAT TO DO
• Unplug the appliance to stop beeping.
• Wait for appliance to cool down to reset operation.
• If food ignites, do not open the door.
• If normal operation does not resume, call the service
agent with information of failure code.
• Unplug the appliance and wait more than 1 minute
and reconnect.
• If normal operation does not resume, call the service
agent with information of failure code.
• Check line frequency and reconnect to the right
power source.
PROGRAM
1
2
3
TIME
MICRO
%
PREHEAT
CONV