Rangemaster Double Built in Oven Oven User Manual


 
INSTALLATION
Page 13
Replacing the oven light bulb
Warning: Switch off the mains
electricity supply to the oven.
The oven light is positioned in the top
left hand corner of the oven interior. If
the light bulb needs replacing, unscrew
the protective cover by turning it
anticlockwise and remove the faulty bulb
(see diagram). Fit the replacement bulb
and replaced the protective cover,
screwing it firmly into place.
The catalytic liners (if fitted) are heavily
soiled and difficult to clean
To ensure that the stay-clean linings
operate effectively, the oven should be
heated to at least 200ºC whenever heavy
soiling has occurred during roasting or
grilling. If this is not done, the soiling
burns onto the linings and they become
black and shiny. In this case new liners
must be purchased from your
Rangemaster dealer.
For after sales service see the ‘Customer
Care’ leaflet.
Installation
Warning: This appliance must be
correctly installed by a suitably
qualified person strictly in accordance
with the manufacturer’s instructions.
The manufacturers decline
responsibility for injury or damage to
persons or property as a result of
improper installation of this
appliance.
This appliance conforms to DC No 13/4/
89 and the standards of CEE DTD 87/
308 of 2/6/1987 regarding the
elimination of radio interference.
Electrical connection
Electrical Installation must comply with
all relevant local and national
regulations. Make sure that the voltage
supply is the same as the rating given on
the data plate positioned on the lower
part of the front of the oven.
This appliance must be connection to an
A.C. single phase 230 V, 50 Hz
electricity supply. The total rated load is
3.9kW.
The oven must be connected to a 30 amp
power supply via a suitable isolator with
an on-off switch, and protected by a 30
amp fuse. The isolator should be easily
accessible in case of maintenance or
emergency.
This appliance is supplied without a
connection cable. A suitable cable,
which complies with all local and
national regulations, must be used. This
should be of type H05 RR-F, 3-core, and
with a minimum sectional area of 2.5
mm.