INSTALLATION
Page 14
The connection clamp for the cable is at
the rear of the appliance. Unscrew and
remove the cover then insert the cable by
way of the cable clip and connect.
Warning: This appliance must be
earthed.
The earth conductor of the mains cable
must be longer than the other two
conductors; in order that it would
become disconnected last should the
cable be pulled or work loose following
installation. Secure the cable by
tightening the cable clip screws fully,
then replace and secure the cover.
Built-in installation
This appliance is designed for building-
in to a standard 600mm wide oven
housing.
The housing, adjacent furniture and all
materials used in installation must be
able to withstand a minimum
temperature of 80ºC plus ambient
temperature during periods of operation.
In addition, adjacent furniture cabinet
doors must be at least 8mm from the
appliance at all points. Certain types of
vinyl or laminate kitchen furniture
cabinetry are particularly prone to heat
damage and discolouration, Any
delamination or discolouration of
materials which occurs below 80ºC plus
ambient temperature or where materials
are less than 8mm from the appliance
will be the liability of the owner.
The housing into which the appliance is
installed must incorporate a full depth
shelf positioned 50mm below the
support shelf for the appliance.
For building-in to a tall housing, the
installation dimensions are as follows: