F04: <Purpose> Simply passing through if entered by mistake.
<Operation> Press SET key in “F04” displayed to revert to PV display.
F05: <Purpose> Compressor is turned on with forcibly delayed (by minute increment)
when the power retrieves from the power failure.
<Operation> Input “F05” and press SET key to display “002” (initial).
Change the value in the range “002”~”015” with key and key.
Press SET key to store the value and revert to PV display.
F06: <Purpose> Dividing F-code for customer used from service
<Operation> Input F06 and press SET key to display “000” (initial value).
Set to “384” with key and key. Press SET key to store the
value and revert to PV display.
<Cancel> Input F06 and press SET key to display “384”.
Change to “000” with key and key. Press SET key to store
the value and revert to PV display.
Turn the power off then on to revert to “000”. (not stored in
non-volatile memory)
Note) “384” is stored in non-volatile memory during battery back-up.
(battery SW is ON)
F07: <Purpose> To match temperature of temp. sensor with temperature of center at
the chamber.
<Operation> Input service code in F06 prior to use this mode.
Input F07 and press SET key to display “00.0” (initial value).
Change to the desired value with key and key in the range of
“-4.9”~”04.9”.
Press SET key to store the value and revert to PV display.
F08: <Purpose> Simply passing through if entered by mistake.
<Operation> Press SET key in “F08” displayed to revert to PV display.
Buzzer tone is emitted if service code is not input in F06.
F12: <Purpose> To display the temperature of temp. sensor
<Operation> Input service code in F06 prior to use this mode.
Input F12 and press SET key to display alternately F12 and “XX.X”
(present internal temperature). Press SET key to revert to PV
display. 3 digits indication. Minus “-“ is not indicated.
Ex)
“-85.5 㸢㩷 indicated as “85.5”
“-79.5㸢㩷 indicated as “-80”
F13: <Purpose> Simply passing through if entered by mistake.
<Operation> Press SET key in “F13” displayed to revert to PV display.
Buzzer tone is emitted if service code is not input in F06.
F14: <Purpose> To display the temperature of Comp. sensor
<Operation> Input service code in F06 prior to use this mode.
Input F14 and press SET key to display alternately F14 and “XX.X”
(present temperature of Comp. sensor). Press SET key to revert to
PV display.
F15: <Purpose> Simply passing through if entered by mistake.
<Operation> Press SET key in “F15” displayed to revert to PV display.
Buzzer tone is emitted if service code is not input in F06.